Chopper pumps - Alligator

Submersible sewage pumps with self cleaning semi-open OC impeller with cutting edges

50 Hz

Specifications:

Discharge size
DN80 - DN100

Max. head
32,9 - 51,5 m

Max. flow
122,0 - 130,3 m³/h

Motor power P1
7,3 - 16,0 kW

Motor power P2
6,4 - 14,4 kW

Speed
2.900 / 1.450 rpm

Characteristics

Chopper pumps - Alligator

Application

Wastewater disposal with small pipe cross-sections, high heads at medium flow rates. The Alligator models shred entrained solids in fractions of a second.

Installation

Single-stage submersible pumps in close-coupled design for permanent or transportable usage.

Materials

Motor housing, Pump housing, Suction cover (Grey cast iron EN-GJL-250), Laufrad, Schleißwand (Hard cast iron EN-GJN-HB555 (XCr23)), Motor shaft (Stainless steel), Mechanical seal (SiC), Cooling jacket (Version U/ET) (Stainless steel), Elastomere (NBR)

Pumped liquid

Waste water or sewage containing solids. Max. liquid temperature: 40°C, short term up to 60°C.

Motor

Three phase electric motor with 2-pole winding. Insulation class H (180 C), Protection IP 68.

Shaft/Bearing

Large diameter stainless steel rotor shaft, pre-lubricated bearings.

Explosion protection

In addition to the standard version, selected motors are also available explosion proof according to ATEX EX II 2 G Ex c d II B T4,(T3).

Seals

Two independently working silicon-carbide mechanical seals in tandem-arrangement. Oil-filled seal chamber with possibility of control by the inspection screw.

Features

EffTec versions with patented PermaCool system: The newly developed PermaCool system is trend-setting. This permanent motor cooling system now allows either wet or dry installation. At the same time, the new, patented design ensures that the cooling jacket cannot become clogged with solids.

The network frequency is 50 Hz in the EU.
In other parts of the world, such as in the North American region, Brazil, Saudi Arabia or South Korea 60 Hz.

HOMA pumps are available for both frequency ranges. A selection of the pumps for the valid frequency range at the installation site must be made accordingly. We are happy to assist you in the selection of the right pumps.


Select 50 Hz

Select 60 Hz

At this point, you exit the HOMA website and are directed to the website offering our pump selection software HOP.Sel.

Frequency

50 Hz