Submersible pumps for sewage and effluent - V(X)
Submersible sewage pumps with vortex impeller

Specifications:
Spherical clearance
80 - 100 mm
Discharge size
DN80 - DN100
Max. head
7,0 - 53,8 m
Max. flow
54,0 - 228,0 m³/h
Motor power P2
1,3 - 25,4 kW
Speed
2900 / 1450 / 960 rpm
Characteristics
Submersible pumps for sewage and effluent - V(X)
Application
Pump is suitable for pumping sewage, effluents, sludge, surface water, liquids containing a high level of impurities or fibrous matter and liquids containing gas.
Installation
Single-stage submersible pumps in close-coupled design for permanent or transportable usage.
Materials
Motor housing (Grey cast iron EN-GJL-250), Pump housing (Grey cast iron EN-GJL-250), Impeller (Grey cast iron EN-GJL-250), Motor shaft (Stainless steel 1.4104), Bolts (Stainless steel), Elastomeres (Nitrile Rubber), Mechanical seal on medium side (SiC / SiC), Mechanical seal on motor side (SiC / SiC), Upper Bearing (Deep Groove Ball Bearing), Lower Bearing (Two angular ball bearings).
Pumped liquid
Max. medium temperature: 40 °C.
Motor
Three phase electric motor with 2-, 4-, or 6-pole winding. Insulation class H (180 C), Protection IP 68. With seal monitoring in the oil barrier chamber as standard.
Shaft/Bearing
Large diameter stainless steel rotor shaft, pre-lubricated bearings.
Explosion protection
In addition to the standard version, all motors are available explosion proof according to II 2 G Ex c d [e] [ib] IIB T4, T3.
Seals
Two independently working silicon-carbide mechanical seals in tandem-arrangement. Oil-filled seal chamber with possibility of control by the inspection screw.
Impeller
Impeller of the V(X) series.
For optimum adaptation to the pump medium and operating conditions.
Vortex impeller
For coarse and fibrous polluted, braid-forming and gaseous media.
The network frequency is 50 Hz in the EU.
In other parts of the world, such as in the North American region, Brazil, Saudi Arabia or South Korea 60 Hz.
HOMA pumps are available for both frequency ranges. A selection of the pumps for the valid frequency range at the installation site must be made accordingly. We are happy to assist you in the selection of the right pumps.
At this point, you exit the HOMA website and are directed to the website offering our pump selection software HOP.Sel.
Frequency
50 Hz